LaneRuler - automated lane tracking software for electrophoresis gels
-
by
Richard Wong
—
published
Apr 25, 2007
—
last modified
Jun 04, 2010 03:45 PM
This is a short tutorial on the LaneRuler software suite. The core module is a command line c program, whose result can be reviewed and corrected using a java interface. The tutorial will go through the flow of the program, various flags for specifying the format of the gel, and details about all the options available.
Located in
Platforms
/
…
/
Documentation
/
LaneRuler Documentation
-
cDNA gel
-
by
Richard Wong
—
published
Apr 24, 2007
—
last modified
Jun 04, 2010 03:46 PM
Sample lane tracking result for a cDNA gel.
Located in
Platforms
/
…
/
Documentation
/
LaneRuler Documentation
-
PCR gel
-
by
Richard Wong
—
published
Apr 24, 2007
—
last modified
Jun 04, 2010 03:46 PM
Sample lane tracking result for a PCR gel.
Located in
Platforms
/
…
/
Documentation
/
LaneRuler Documentation
-
DNA fingerprinting gel
-
by
Richard Wong
—
published
Apr 24, 2007
—
last modified
Jun 04, 2010 03:46 PM
Sample lane tracking result for a DNA fingerprinting gel.
Located in
Platforms
/
…
/
Documentation
/
LaneRuler Documentation
-
Lane tracking result for a sample DNA fingerprinting gel
-
by
Richard Wong
—
published
Apr 24, 2007
—
last modified
Jun 04, 2010 03:45 PM
Ran with default parameters.
Function call: >findlanes -p <project_directory>
Located in
Platforms
/
…
/
Documentation
/
LaneRuler Documentation
-
Sample lane tracking result for a PCR gel.
-
by
Richard Wong
—
published
Apr 24, 2007
—
last modified
Jun 04, 2010 03:45 PM
Due to low data density, toneadjustment was turned off.
Function call: >findlanes -p <project_directory> -a
Located in
Platforms
/
…
/
Documentation
/
LaneRuler Documentation
-
Sample lane tracking result for a cDNA gel.
-
by
Richard Wong
—
published
Apr 24, 2007
—
last modified
Jun 04, 2010 03:45 PM
A rotation was required as the gel initially had wells at top edge of the image. Due to low number of marker lanes, we match all peaks in all zones (-i). Tone adjustment was not done due to high data signal (-a). The morphology element size was adjusted since the marker band separation to image width ratio has changed significantly.
Function call: >findlanes --numlanes 11 --markerperiod 10 --orientation 1 -a -i --morphelement 150
Located in
Platforms
/
…
/
Documentation
/
LaneRuler Documentation
-
LaneRuler usage flow chart
-
by
Richard Wong
—
published
Apr 24, 2007
—
last modified
Jun 04, 2010 03:45 PM
Located in
Platforms
/
…
/
Documentation
/
LaneRuler Documentation
-
Control bar of the LaneRulerUI interface
-
by
Richard Wong
—
published
Apr 24, 2007
—
last modified
Jun 04, 2010 03:45 PM
Located in
Platforms
/
…
/
Documentation
/
LaneRuler Documentation
-
Panel for parameter specification for the lane adjustment interface
-
by
Richard Wong
—
published
Apr 24, 2007
—
last modified
Jun 04, 2010 03:45 PM
Located in
Platforms
/
…
/
Documentation
/
LaneRuler Documentation